        Welcome to the website of Baoji Zhongheng Instrument Co., Ltd. Tel:+86-917-3512881
        Differential pressure transmitter Single crystal silicon pressure transmitter Electromagnetic flowmeter Capacitive pressure transmitter High precision pressure transmitter Intelligent pressure switch Diffused silicon pressure transmitter Flow switch Intelligent pressure transfer controller Thermometer

        Pressure transmitter


        BXY6012/13- Differential Press

        Product code

         

        Overview

        Product quotationProduct consulting

        Product introduction

        BXY6012 Differential Pressure Installation Gauge
        transmitter
        BXY6013- Differential pressure installation absolute pressure
        transmitter
        BXY6012/3-Differential pressure mounted gauge/absolute pressure transmitter is used to measure the liquid level, density, and pressure of liquids, gases, or vapors, and then convert it into a 4-20mADC HART current signal output. BXY6012/3 can also communicate with RST375 handheld terminals or RSM100 Modems for parameter setting, process monitoring, etc.
        Standard specifications
        (Calibrate the range based on the standard zero point, stainless steel 316L diaphragm, filled with silicone oil)
        1 Performance specifications
        Reference accuracy for range adjustment
        (Including linearity, backlash, and repeatability from zero)
        ± 0.075%
        If TD>10 (TD=maximum range/adjustment range), then it is:
        ± (0.0075 × TD)%
        Environmental temperature impact


        Range code

        -20℃~65℃Total impact amount

        B/L

        ±(0.30×TD+0.20)%×Span

        other

        ±(0.20×TD+0.10)%×Span

        Range code

        -40℃~-20℃和65℃~85℃Total impact amount

        B/L

        ±(0.30×TD+0.20)%×Span

        other

        ±(0.20×TD+0.10)%×Span


        Overrange impact:±0.075%×Span


        Long term stability

        Range code

        influence quantity

        B/L

        ±0.2%×Span/1year

        other

        ±0.1%×Span/1year


        Power impact
        ± 0.001%/10V (12-42V DC), negligible
        2 Functional specifications
        Range and range (BXY6012 gauge pressure transmitter)


        Range/Range

        kPa

        bar

        B

        Range

        0.6~6

        6~60mbar

        Range

        -6~6

        -60~60mbar

        C

        Range

        2~40

        0.02~0.4

        Range

        -40~40

        -0.4~0.4

        D

        Range

        2.5~250

        0.025~2.5

        Range

        -100~250

        -1~2.5

        F

        Range

        30~3000

        0.3~30

        Range

        -100~3000

        -1~30

        G

        Range

        0.1~10MPa

        1~100

        Range

        -0.1~10MPa

        -1~100

        H

        Range

        0.21~21 MPa

        2.1~210

        Range

        -0.1~21 MPa

        -1~210

        I

        Range

        0.4~40 MPa

        4~400

        Range

        -0.1~40 MPa

        -1~400


        Range and Range (BXY6013 Absolute Pressure Transmitter)

        Range and Range

        kPa

        bar

        L

        Range

        2~40

        0.02~0.4

        Range

        0~40

        0~0.4

        M

        Range

        2.5~250

        0.025~2.5

        Range

        0~250

        0~2.5

        O

        Range

        30~3000

        0.3~30

        Range

        0~3000

        0~30


        Range limit
        Within the upper and lower limits of the range, it can be adjusted arbitrarily. It is recommended to select range codes with the lowest possible range ratio to optimize performance characteristics.
        Zero point setting
        The zero point and range can be adjusted to any value within the measurement range in the table, as long as the calibrated range is ≥ the minimum range
        Installation position impact
        The change in installation position parallel to the film surface will not cause zero drift effect. If the change in installation position exceeds 90 ° with the film surface and there is a zero position effect within the range of<0.4kPa, it can be corrected by adjusting zero. No range impact.
        output
        2-wire system, 4-20mADC, selectable for digital communication with HART output, with options for linear or square root output.
        Output signal limit: Imin=3.9mA, Imax=20.mA
        Alarm current
        Low alarm mode (minimum): 3.7 mA
        High alarm mode (maximum): 21 mA
        No alarm mode (hold): maintain the effective current value before the fault
        Alarm current standard setting: high alarm mode
        response time
        The damping constant of the amplifier component is 0.1s; The sensor time constant is between 0.1 and 1.6 seconds, depending on the range and range ratio. The additional adjustable time constant is 0.1~60s.
        Preheating time:<15s
        ambient temperature
        -40-85 ℃
        When equipped with LCD display and fluororubber sealing ring, -20~65 ℃
        Storage temperature/transportation temperature
        -50-85 ℃
        With LCD display: -40~85 ℃
        Pressure limit: from vacuum to maximum range.
        Overload limit:


        range

        6kPa

        (1B)

        40kPa

        (1C/1L)

        250kPa

        (1D/1M)

        Overload limit

        16MPa

        16MPa

        16MPa

        range

        2(3)MPa

        (1E/1O)

        10MPa

        (1G)

        21MPa

        (1H)

        40MPa

        (1I)

        Overload limit

        16MPa

        20MPa

        25MPa

        45MPa


        Electromagnetic compatibility (EMC): see "Electromagnetic Compatibility Schedule" on the next page
        3 Installation
        Power supply and load conditions
        The power supply voltage is 24V, R ≤ (Us-12V)/Imax k Ω
        Where Imax=23 mA
        Maximum power supply voltage: 42VDC
        Minimum power supply voltage: 12VDC, 15VDC (backlight LCD display)
        Digital communication load range: 230~600 Ω
        Electrical connections
        M20X1.5 cable sealing buckle and wiring terminal are suitable for wires ranging from 0.5 to 2.5mm2.
        Process Connection
        The end face of the process connection flange has NPT 1/4 and UNF 7/16 internal threads.
        4 Physical specifications
        material quality
        Diaphragm: stainless steel 316L, Hastelloy C
        Process connection: stainless steel 316L
        Filling fluid: silicone oil
        Transmitter housing: aluminum alloy material, with epoxy resin sprayed on the surface
        Shell sealing ring: nitrile rubber (NBR)
        Nameplate: stainless steel 304
        weight
        3.3kg (without LCD display, mounting bracket, process connection)
        Shell protection level: IP67
        Electromagnetic Compatibility Schedule

        (1) A performance level description: During testing, the performance was normal within the technical specification limits.
        (2) B performance level description: During testing, the function or performance is temporarily reduced or lost, but it can recover on its own, and the actual operating status, storage, and data remain unchanged.
        External dimension unit (mm)

        Wall mounted connection method Vertical piping connection method


        5 Electrical connection diagram



        Note: The quick interface function is equivalent to the signal terminal.
        6 Process Connection Instructions











        ?