        Welcome to the website of Baoji Zhongheng Instrument Co., Ltd. Tel:+86-917-3512881
        Differential pressure transmitter Single crystal silicon pressure transmitter Electromagnetic flowmeter Capacitive pressure transmitter High precision pressure transmitter Intelligent pressure switch Diffused silicon pressure transmitter Flow switch Intelligent pressure transfer controller Thermometer

        Pressure transmitter


        BXY6002 gauge pressure/BXY6003

        Product code

         

        Overview

        Product quotationProduct consulting

        Product introduction

        BXY6002 gauge pressure remote transmitter

        BXY6003 Absolute Pressure Remote Transmission Transmitter


        1 Application
        The diaphragm box of the remote transmitter is used to prevent the medium in the pipeline from directly entering the pressure sensor component of the transmitter. It uses silicone oil and other filling liquids to transmit pressure between the transmitter and it.
        The BXY6002/3 gauge/absolute pressure remote transmitter is used to measure the liquid level, density, and pressure of liquids, gases, or vapors, and then convert them into 4- 20mADC HART current signals for output. BXY6002/3 can also communicate with RST375 handheld terminals or RSM100 Modems for parameter setting, process monitoring, etc. The measurement range of the BXY6002/3 gauge/absolute pressure remote transmitter (when not relocated) is 0- 6kPa~25MPa, and the rated pressure of the remote flange is 1.6/4MPa, 6.4MPa, 10MPa, 150psi, 300psi, or 600psi, respectively.
        2 Working Principle and Structure
        The BXY6002/3 gauge/absolute pressure remote transmitter consists of a BXY6002/3 series gauge/absolute pressure transmitter and a welded and installed capillary remote flange. Its working principle is the same as the BXY6002/3 series gauge/absolute pressure transmitter (refer to the technical specifications of the BXY6002/3 series gauge/absolute pressure transmitter), but the pressure transmission path is slightly different: the pressure acting on the remote flange side first passes through the diaphragm and filling liquid on the remote flange, then through the capillary, and finally reaches the measurement end of the measurement sensor.
        3 inputs
        Measurement parameters: gauge pressure, absolute pressure, liquid level
        measuring range
        Gauge pressure remote transmitter:
        Lower limit value: from -100% URL (continuously adjustable)
        Upper limit value: to+100% URL (continuously adjustable)
        Absolute pressure remote transmitter:
        Lower limit value: from 0 to 100% URL (continuously adjustable)
        Upper limit value: to+100% URL (continuously adjustable)
        range
        Table 1 Comparison Table of Range Code and Range Range Relationship



        Range code


        minimum range

        maximum range

        Rated pressure (maximum)

        C

        6kPa

        40kPa

        Rated pressure of

        liquid level flange

        D

        25kPa

        250kPa

        F

        30kPa

        3MPa

        G

        1MPa

        10MPa

        H

        2.1MPa

        21MPa

        I

        4MPa

        40MPa

        L

        6kPa Absolute pressure

        40kPa Absolute pressure

        M

        25kPaAbsolute pressure

        250kPa Absolute pressure

        O

        30kPa Absolute pressure

        3MPa Absolute pressure

        Table 2 Comparison Table of the Relationship between Remote Transmission Flange and Minimum Range

        flange

        Nominal diameter

        Min/Max Range

        Maximum capillary length

        Flat type

        DN 25/1”

        160kPa/25MPa

        10m

        DN 50/2”

        10kPa/10MPa

        12m

        DN 80/3”

        6kPa/10MPa

        16m

        DN 4”

        6kPa/3MPa

        16m

        plug-in

        DN 50/2”

        16kPa/10MPa

        10m

        DN 80/2”

        6kPa/10MPa

        16m

        DN 4”

        6kPa/3MPa

        16m

        Thread mounted

        remote transmission


        outside diameter

        109mm

        160kPa/25MPa

        10m

        The minimum range of gauge/absolute pressure remote transmitter should be Table 1 and Table 2
        The larger value of the minimum range in. The adjusted range shall not be less than the minimum range. The maximum range of the gauge/absolute pressure remote transmitter should be the minimum of the maximum range of the transmitter body and the rated pressure of the remote flange.
        4 output signals
        2-wire system, 4-20mADC HART output, digital communication, with HART protocol loaded on 4-20mADC signal.
        Output signal limit: Imin=3.9mA, Imax=20.mA
        Alarm current (mode can be set)
        Low alarm mode (minimum): 3.7 mA
        High alarm mode (maximum): 21 mA
        No alarm mode (hold): maintain the effective current value before the fault
        Alarm current standard setting: high alarm mode
        5 Response time
        The damping constant of the amplifier component is 0.1s; The time constant of the sensor and remote flange is 0.2-6s, depending on the sensor's range, range ratio, capillary length, and the viscosity of the filled liquid. The additional adjustable time constant is 0.1~60s.
        6 General conditions
        6.1 Installation conditions
        Gauge/absolute pressure remote transmitters without capillaries can be installed directly through remote flanges, and positional deviations will result in correctable zero offset. The electronic watch case can rotate up to 360 °, and the positioning screw can fix it in any position.
        The gauge/absolute pressure remote transmission flange is connected to a matching flange that complies with ANSI/DIN standards. The matching flange should be equipped with soft gaskets and fixed bolts and nuts (users can choose to install bolts and nuts).
        For gauge/absolute pressure remote transmitters with capillary tubes, if the remote sealing device is lower than the transmitter body, the maximum height difference between the remote sealing device and the transmitter body should be<5m. When the working pressure is below 100kPa absolute pressure, the transmitter body must be lower than the remote sealing device.
        The minimum bending radius of the capillary is 75mm, and winding is strictly prohibited!
        6.2 Environmental conditions
        ambient temperature
        Minimum: depending on the filling fluid
        Maximum: 85 ℃
        When equipped with LCD display and fluororubber sealing ring, -20~65 ℃
        Storage temperature/transportation temperature
        Minimum: depending on the filling fluid
        Maximum: 85 ℃
        Relative humidity: 0-100%
        Impact resistance
        Acceleration: 50g
        Duration: 11ms
        Anti vibration
        2g to 500Hz
        Electromagnetic compatibility (EMC)
        See Table 4 "Electromagnetic Compatibility Schedule" on the next page
        6.3 Process Medium Temperature Limit
        Medium temperature: -30~400 ℃
        Table 3 Relationship between Filling Fluid, Working Temperature, and Minimum Working Pressure


        Fill Fluid

        silicone oil

        (S)

        High temperature

        silicone oil(H)

        Ultra high

        temperature silicone oil(U)

        vegetable oil(V)

        density25℃

        960

        kg/m3

        980

        kg/m3

        1020

        kg/m3

        937

        kg/m3

        Operating temperature

        range


        -30~

        200℃

        -10~

        350℃

        -10~

        400℃

        0~

        250℃


        temperature

        Working pressure range (kPa absolute pressure)

        20℃

        >10

        >10

        >10

        >25

        100℃

        >25

        >25

        >25

        >50

        150℃

        >50

        >50

        >50

        >75

        200℃

        >75

        >75

        >75

        >100

        250℃


        >100

        >100

        >100

        350℃


        >100

        >100


        400℃



        >100


        Note: If the working temperature and pressure relationship exceeds the above range, it should be specially pointed out that special designs can be used to meet the requirements.
        Pressure limit of transmitter body: vacuum to maximum pressure
        Rated pressure of remote transmission flange:
        ANSI standard: 150psi~600psi
        DIN standard: PN 1.6MPa~PN 10MPa
        weight
        DN 50/2 "is about 7-10kg, DN 80/3" is about 8-11kg, and DN 4 "is about 9-12kg.
        Explosion proof performance
        NEPSI Flameproof License: Ex d Ⅱ C T6
        NEPSI Intrinsic Safety License: Ex ia IIC T4
        Permissible operating temperature: -40 ℃~65 ℃
        6.4 Power supply and load conditions
        The power supply voltage is 24V
        R ≤ (Us-12V)/Imax k Ω
        Where Imax=23 mA
        Maximum power supply voltage: 42VDC
        Minimum power supply voltage: 12VDC, 15VDC (backlight LCD display)
        Digital communication load range: 250~600 Ω
        material quality
        Measurement capsule: stainless steel 316L
        Diaphragm: stainless steel 316L, Hastelloy C, tantalum
        Process flange: stainless steel 304
        Filling fluid: silicone oil, high-temperature silicone oil, ultra-high temperature silicone oil, vegetable oil
        Transmitter housing: aluminum alloy material, with epoxy resin sprayed on the surface
        Shell sealing ring: nitrile rubber (NBR)
        Nameplate: stainless steel 304
        Electrical connections
        M20X1.5 cable sealing buckle and wiring terminal are suitable for wires ranging from 0.5 to 2.5mm2.
        Process Connection
        The remote flange complies with ANSI or DIN standards. Can be installed directly, please refer to the dimension diagram.
        Shell protection level: IP67
        ———————————————————————————— ————————————————
        Table 4 Electromagnetic Compatibility Schedule


        Serial

        Number

        Test items

        Basic standards

        Test conditions

        Performance

        Level

        1

        Radiated interference (shell)

        GB/T 9254-2008Table 5

        30MHz~1000MHz

        qualified

        2

        Conducted interference
        (DC power port)


        GB/T 9254-2008Table 1

        0.15MHz~30MHz

        qualified

        3

        Electrostatic discharge

        (ESD) immunity

        GB/T 17626.2- 2006

        4kV(Contact point)

        8kV(air)

        B

        4

        Radio frequency electromagnetic

        field immunity

        GB/T 17626.3-2006

        10V/m (80MHz~1GHz)

        A

        5

        Power frequency magnetic

        field immunity

        GB/T 17626.8- 2006

        30A/m

        A

        6

        Electrical fast transient

        pulse group immunity

        GB/T 17626.4-2008

        2kV(5/50ns,5kHz)

        B

        7

        Surge immunity

        GB/T 17626.5-2008

        1kV(Between lines)

        2kV(Between lines)(1.2us/50us)

        B

        8

        Immunity to conducted

        interference induced

        by radio frequency fields

        GB/T 17626.6-2008

        3V (150KHz~80MHz)

        A

        Note: (1) A performance level description: During testing, the performance is normal within the technical specification limits.
        (2) Performance level description: During testing, the function or performance temporarily decreases or is lost, but can be restored on its own. The actual operating status, storage, and data do not change
        7 Dimensions in millimeters
        Figure 1 Basic Remote Sealing Device Diagram (RS Type)

        Figure 2 Basic Remote Sealing Device Direct Installation Diagram (RN Type)






        ?