1. <code id="cul58"></code>
      <ul id="cul58"></ul>
      <strike id="cul58"></strike>
      1. <tbody id="cul58"></tbody>
        <dl id="cul58"><s id="cul58"></s></dl>

        Welcome to the website of Baoji Zhongheng Instrument Co., Ltd. Tel:+86-917-3512881
        Differential pressure transmitter Single crystal silicon pressure transmitter Electromagnetic flowmeter Capacitive pressure transmitter High precision pressure transmitter Intelligent pressure switch Diffused silicon pressure transmitter Flow switch Intelligent pressure transfer controller Thermometer

        Liquid level transmitter


        BXY6001 Differential Pressure

        Product code

         

        Overview

        Product quotationProduct consulting

        Product introduction

        The thermal flow switch adopts precision electronic components widely used in aviation and automobiles, and its reliable and stable circuit design makes the flow signal more accurate and stable. Currently, it has been widely used in industries such as steel, metallurgy, pharmaceuticals, and chemical engineering
        The ZH-L2 thermal flow switch is an upgraded version of the ZH-L1 model, which not only has more prominent improvements in the signal processing of the flow switch probe, but also makes the HL-L2 software operation and control functions more powerful; Easy to operate and easy to install.

        The measuring principle of the ZH-L2 thermal flow switch is the same as that of the ZH-L1, and it is also designed based on the principle of heat exchange. The probe is equipped with a heating module and a heat sensing module, and the heat dissipation of the heating module is closely related to the flow rate of the measured fluid. If there is no medium flow in the pipeline, the signal received by the heat sensing circuit is a fixed value; When the fluid medium flows through the probe, the signal received by the thermal circuit changes with the flow rate of the medium. The thermal circuit converts the temperature difference signal between the heating module and the thermal module into an electrical signal, and the processor then converts it into signals such as PNP/NPN/4-20mA/relay for output.
        Gas liquid dual purpose, can be used for gas and hydraulic systems, circulating water, cutting fluid and lubricating oil cutoff monitoring, and pump idle protection.

        Range code


        minimum range

        maximum range

        Rated pressure (maximum)

        B

        1kPa

        6kPa

        Rated pressure of liquid level flange

        C

        4kPa

        40kPa

        D

        25kPa

        250kPa

        E

        200kPa

        2MPa

        Table 2 Comparison Table of the Relationship between Liquid Level Flange and Minimum Range

        Level flange

        Nominal diameter

        minimum range

        Flat type

        DN 50/2”

        10kPa

        DN 80/3”

        1kPa

        DN 4”

        1kPa

        plug-in

        DN 50/2”

        16kPa

        DN 80/2”

        1kPa

        DN 4”

        1kPa

        The minimum range of the differential pressure liquid level transmitter should be the larger value of the minimum range in Table 1 and Table 2. The adjusted range shall not be less than the minimum range. The maximum range of the liquid level transmitter should be the minimum of the maximum range of the transmitter body and the rated pressure of the liquid level flange.
        4 output signals
        2-wire system, 4-20mADC HART output, digital communication, with HART protocol loaded on 4-20mADC signal.
        Output signal limit: Imin=3.9mA, Imax=20.mA
        Alarm current (mode can be set)
        Low alarm mode (minimum): 3.7 mA
        High alarm mode (maximum): 21 mA
        No alarm mode (hold): maintain the effective current value before the fault
        Alarm current standard setting: high alarm mode
        5 Response time
        The damping constant of the amplifier component is 0.1s; The time constant of the sensor and liquid level flange is 0.2-2 seconds, depending on the range and range ratio. The additional adjustable time constant is 0.1~60s.
        6 General conditions
        6.1 Installation conditions
        The liquid level flange transmitter can be directly fixed in any position. The optimal state is to keep the process flange axis in a vertical position, and the positional deviation will result in a correctable zero offset. The electronic watch case can rotate up to 360 °, and the positioning screw can fix it in any position.
        6.2 Environmental conditions
        ambient temperature
        Minimum: depending on the filling fluid
        Maximum: 85 ℃
        When equipped with LCD display and fluororubber sealing ring, -20~65 ℃
        Storage temperature/transportation temperature
        Minimum: depending on the filling fluid
        Maximum: 85 ℃
        Relative humidity
        0-100%
        Impact resistance
        Acceleration: 50g
        Duration: 11ms
        Anti vibration
        2g to 500Hz
        Electromagnetic compatibility (EMC)
        See Table 3 "Electromagnetic Compatibility Schedule" on the next page
        6.3 Process Medium Limits
        Medium temperature limit: -30~180 ℃
        Transmitter body pressure limit
        From an absolute pressure of 3.5kPa to the rated pressure, the protective pressure can be greater than 1.5 times the rated pressure and applied to both sides of the transmitter.
        Rated pressure of liquid level flange
        ANSI standard: 150psi~600psi
        DIN standard: PN 1.6MPa~PN 10MPa
        Unidirectional overload limit
        The low pressure side is the rated pressure of the transmitter body, and the high pressure side is the rated pressure of the liquid level flange, which may cause adjustable zero drift.
        Weight: DN 50/2 "approximately 7-10kg; DN 80/3 "approximately 8-11kg; DN 4 "is approximately 9-12kg.
        Explosion proof performance
        NEPSI Flameproof License: Ex d Ⅱ C T6
        NEPSI Intrinsic Safety License: Ex ia IIC T4
        Permissible operating temperature: -40 ℃~65 ℃
        6.4 Power supply and load conditions
        The power supply voltage is 24V
        R ≤ (Us-12V)/Imax k Ω
        Where Imax=23 mA
        Maximum power supply voltage: 42VDC
        Minimum power supply voltage


        Serial Number

        Test items

        Basic standards

        Test conditions

        Performance Level

        1

        Radiated interference (shell)

        GB/T 9254-2008表5

        30MHz~1000MHz

        qualified

        2

        Conducted interference
        (DC power port)


        GB/T 9254-2008表1

        0.15MHz~30MHz

        qualified

        3

        Electrostatic discharge (ESD) immunity

        GB/T 17626.2-2006

        4kV(觸點(diǎn))

        8kV(空氣)

        B

        4

        Radio frequency electromagnetic field immunity

        GB/T 17626.3-2006

        10V/m (80MHz~1GHz)

        A

        5

        Power frequency magnetic field immunity

        GB/T 17626.8-2006

        30A/m

        A

        6

        Electrical fast transient pulse group immunity

        GB/T 17626.4-2008

        2kV(5/50ns,5kHz)

        B

        7

        Surge immunity

        GB/T 17626.5-2008

        1kV(Between lines)

        2kV(Between lines)(1.2us/50us)

        B

        8

        Immunity to conducted interference induced by radio frequency fields

        GB/T 17626.6-2008

        3V (150KHz~80MHz)

        A

        Note: (1) A performance level description: During testing, the performance is normal within the technical specification limits.
        (2) B performance level description: During testing, the function or performance is temporarily reduced or lost, but it can recover on its own, and the actual operating status, storage, and data remain unchanged.
        External dimension unit (mm)


        Table 4 Structural dimensions of liquid level flange

        Nominal diameter

        Rated pressure

        ΦD

        ΦK

        Φd1

        Φd2

        Φd3

        t

        b

        Required bolts

        plug-in

        Flat type

        number

        thread

        DN 50

        PN1.6/4MPa

        165

        125

        48.3

        57

        102

        3+0.5

        20

        4

        M16

        (Sealing surfaceDIN 2526E

        PN 6.4MPa

        18

        135

        48.3

        57

        102

        3+0.5

        26

        4

        M20

        (flangeDIN 2501)

        PN 10MPa

        195

        145

        48.3

        57

        102

        3+0.5

        28

        4

        M20

        DN 80

        PN1.6/4MPa

        200

        160

        76

        75

        138

        3+0.5

        24

        8

        M16

        (Sealing surface DIN 2526E type)

        PN 6.4MPa

        215

        170

        76

        75

        138

        3+0.5

        28

        8

        M20

        (Flange DIN 2501)

        PN 10MPa

        230

        180

        76

        75

        138

        3+0.5

        32

        8

        M24

        DN 2"
        (ANSI B 16.5 RF)

        150psi

        152.4

        120.6

        48.3

        57

        92.1

        3+0.5

        17.4

        4

        M18

        300psi

        165.1

        127.0

        48.3

        57

        92.1

        3+0.5

        20.6

        8

        M18

        600psi

        165.1

        127.0

        48.3

        57

        92.1

        6.35

        31.75

        8

        M18

        DN 3"
        (ANSI B 16.5 RF)

        150psi

        190.5

        152.4

        76

        75

        127

        3+0.5

        22.2

        4

        M16

        300psi

        209.5

        168.3

        76

        75

        127

        3+0.5

        27.0

        8

        M20

        600psi

        209.5

        168.3

        76

        75

        127

        6.35

        38.05

        8

        M20

        DN 4“

        150psi

        229

        191

        89

        89

        157

        3+0.5

        30

        8

        M18

        (ANSI B 16.5 RF)

        300psi

        255

        200

        89

        89

        157

        3+0.5

        32

        8

        M18

        Note: Users can choose to install bolts and nuts.
        7 Electrical connection diagram


        Note: The quick interface function is equivalent to the signal terminal.
        8. Instructions for Low Voltage End Process Connection










        ?