        Welcome to the website of Baoji Zhongheng Instrument Co., Ltd. Tel:+86-917-3512881
        Differential pressure transmitter Single crystal silicon pressure transmitter Electromagnetic flowmeter Capacitive pressure transmitter High precision pressure transmitter Intelligent pressure switch Diffused silicon pressure transmitter Flow switch Intelligent pressure transfer controller Thermometer

        BXY65M20W-2

        Product code

         

        Overview

        Installation of 100 standard instruments 4 digit
        Product quotationProduct consulting

        Product introduction


        1、 Overview
        This series of temperature controllers is an intelligent digital temperature measurement and control product that integrates temperature measurement, display, output, and control. This product is a fully electronic structure, with a front end equipped with an isolation film filled oil pressure resistance temperature sensor. It is converted by high-precision A/D, processed by a microprocessor, displayed on site, and outputs one analog signal and two switching signals.
        This intelligent temperature controller is flexible to use, easy to operate, easy to debug, and safe and reliable. Widely used in industries such as hydropower, tap water, petroleum, chemical, mechanical, hydraulic, etc., for on-site measurement, display, and control of fluid medium temperature
        2、 Characteristics
        Installation of 100 standard instruments
        4 digit LED digital tube display, ignoring value errors
        Two control point relays output 220V 3A
        ◆ 4-20mA standard signal output (optional)
        Control point on-site setting.
        ◆ Optional 24VDC 220VAC power supply
        Three technical parameters

        Mileage range e|
        Accuracy level+
        0.5% 4
        Overload capacity.
        200% 2
        Temperature type+
        Gauge pressure ←
        Stability P
        <0.1% per year+
        Power supply voltage+
        24VDC+
        Display method+
        056 "digital tube+
        Display range 4 | -1999 999942
        Environmental temperature+
        -20C 70CP
        Relative humidity+
        ≤ 80%
        Installation thread+
        M20 * 1.5+
        material quality ρ
        Stainless steel+


        4、 Overall dimensions

        5. Installation
        5.1 Mechanical connection:
        Multiple installation methods, threaded flanges can be directly connected
        5.2 Electrical connections



        6、 Setting functions
        Note: The switching point is determined by the configuration of the pull-in value and release value. When the pull-in value is greater than the release value, it is the upper limit alarm output (normally open function). When the pull-in value is less than the release value, it is the lower limit alarm output (normally closed function). The difference between the pull-in value and the release value is the return difference of the switching point.
        Example: To set the switch point 1 as the upper limit alarm output (normally open function) at 4 ℃ for suction and below 3.9 ℃ for disconnection,; Switch point 2 is the lower limit alarm output (normally closed function) that is disconnected at 10 ℃ and absorbed below 9.9 ℃:
        Enter menu: Settings
        AL1H=4.00 AL1L=3.9
        AL2H=9.9 AL1L=10.00
        Press the "SET" button
        ● Display "LOCK" (prompt for password input)
        Press the ▲ or ▼ keys to enter the password "1",
        Press the "SET" button to confirm
        Press the ▲ or ▼ keys to scroll up or down for menu selection (AL1H, AL1L, AL2H, AL2L, END)
        Press the "SET" button to enter the selected menu.
        Press the ▲ or ▼ keys to change the settings
        Press the "SET" key to confirm, and if necessary, use the ▲ or ▼ keys to select other menus for modification.
        6.1 Output
        This controller has two switching outputs. The corresponding output will switch when the pull-in value of the switching point reaches and reply when the temperature drops below the release value.


        AL1H is the pull-in value of switch 1, AL1L is the release value of switch 1
        AL2H is the pull-in value of switch 2, AL2L is the release value of switch 2
        After completing the modification, select the "END" menu and press the "SET" button to confirm the save and exit.
        If there is no key pressed for 30 seconds, the setting state will automatically exit, but the modified data will not be saved.







        ?